摘    要:采用以陶粒为填料的上向流曝气生物滤池(UBAF)对生物絮凝吸附后的校园生活污水进行处理,考察此系统对CODcr、NH3-N的去除效能以及UBAF抗冲击负荷能力.结果表明,此系统CODdr、NH3-N平均去除率可达88.7%和86.6%.水力负荷在0.6~1.8 m3/(m2·h)范围内变化时,UBAF对CODdr的去除...

关 键 词:上向流曝气生物滤池  水力负荷  容积负荷

Treatment of effluent water from bio-flocculation adsorption technology by UBAF
MA Yan-hua,LIU Shao-gen,CHENG Xiong-jian,SUN Juan-juan.Treatment of effluent water from bio-flocculation adsorption technology by UBAF[J].Industrial Water & Wastewater,2011,42(1):37-41.
Authors:MA Yan-hua  LIU Shao-gen  CHENG Xiong-jian  SUN Juan-juan
Affiliation:MA Yan-hua1,LIU Shao-gen1,2,CHENG Xiong-jian1,SUN Juan-juan1(1.School of Environment and Energy Engineering,Anhui Institute of Architecture and Industry,Hefei 230022,China,2.School of Chemistry and Material Science,University of Science and Technology of China,Hefei 230026,China)
Abstract:Up-flow biological aerated filter(UBAF) filled with ceramics grain was used to treat the domestic sewage of campus discharged from the process of bio-flocculation adsorption;the efficiency of the said system on CODCr and NH3-N removal and its anti-shock loading capability were investigated.The results showed that,the average removal rates of CODCr and NH3-N reached 88.7% and 86.6% respectively.When the hydraulic loading ranged from 0.6 to 1.8 m3/(m2·h),the CODCr removal by UBAF was slightly affected,while the NH3-N removal was significantly affected.When the influent CODCr loading rate was below 4.05 kg/(m3·d),the mass concentration of CODCr in the effluent water could meet the specification for grade 1 level B in GB 18918—2002 Discharge standard of pollutants for municipal wastewater treatment plant,and when it increased to 4.74 kg/(m3·d),the effluent water quality met the grade-2 standard only;when the NH3-N loading rate was below 0.56 kg/(m3·d),the mass concentration of NH3-N in the effluent water could meet the discharge standard grade 1 level B,while it would be substandard when the NH3-N loading rate increased to 0.73 kg/(m3·d).UBAF had a very good efficiency for CODCr and NH3-N removal and a strong anti-shock loading capability;however,its nitrification performance was greatly affected by shock loading.