首页 | 本学科首页   官方微博 | 高级检索  
     


Optimisation of anaerobic/anoxic/oxic process to improve performance and reduce operating costs
Authors:Yongzhen Peng  Xiaolian Wang  Weimin Wu  Jun Li  Jie Fan
Abstract:A laboratory‐scale anaerobic/anoxic/oxic reactor system was used to treat synthetic brewery wastewater for 1 year. The objectives were to enhance denitrifying phosphorus removal, improve biological nutrient removal and reduce operating costs. Three operational strategies were tested: (1) controlling nitrate recirculation to stimulate the growth of denitrifying phosphate‐accumulating organisms; (2) adjusting the volume ratio of the anaerobic/anoxic/oxic zones to enhance anoxic P uptake; (3) bypassing a part of the influent flow into the anoxic zone to maximise anoxic P uptake and denitrification. The results showed that not only was anoxic P uptake enhanced but also energy consumption for aeration could be reduced when the anoxic effluent NO3?‐N concentration was controlled between 1 and 3 mg L?1. The optimal volume ratio of the anaerobic/anoxic/aerobic zones in this system was found to be 1:1:2. The optimal bypass flow ratio was 0.32. The results indicated that the optimal strategies could improve treatment performance and reduce operational costs, but there was still a challenge to treat wastewater with low C/N ratio. Copyright © 2006 Society of Chemical Industry
Keywords:A2O process  denitrifying phosphorus removal  nitrate recirculation ratio  volume ratio of anaerobic/anoxic/oxic zone  bypass flow ratio