Automated retrofit targeting of heat exchanger networks
Authors:Timothy G Walmsley  Nathan S Lal  Petar S Varbanov  Jiří J Klemeš
Affiliation:1.Sustainable Process Integration Laboratory – SPIL, NETME Centre, Faculty of Mechanical Engineering,Brno University of Technology,Brno,Czech Republic;2.Energy Research Centre, School of Engineering,University of Waikato,Hamilton,New Zealand
Abstract:The aim of this paper is to develop a novel heat exchanger network (HEN) retrofit method based on a new automated retrofit targeting (ART) algorithm. ART uses the heat surplus-deficit table (HSDT) in combination with the Bridge Retrofit concepts to generate retrofit bridges option, from which a retrofit design may be formulated. The HSDT is a tabular tool that shows potential for improved re-integration of heat source and sink streams within a HEN. Using the HSDT, retrofit bridges—a set of modifications that links a cooler to a heater to save energy—may be identified, quantified, and compared. The novel retrofit method including the ART algorithm has been successfully implemented in Microsoft ExcelTM to enable analysis of large-scale HENs. A refinery case study with 27 streams and 46 existing heat exchangers demonstrated the retrofit method’s potential. For the case study, the ART algorithm found 68903 feasible unique retrofit opportunities with a minimum 400 kW·unit–1 threshold for heat recovery divided by the number of new units. The most promising retrofit project required 3 new heat exchanger units to achieve a heat savings of 4.24 MW with a favorable annualised profit and a reasonable payback period.