Simulation on thermoelectric device with hydrogen catalytic combustion |
| |
Authors: | Feng Wang Jing ZhouGuoqiang Wang Xinjing Zhou |
| |
Affiliation: | a Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, Ministry of Education, Chongqing 400044, PR China b College of Power Engineering, Chongqing University, Chongqing 400030, PR China |
| |
Abstract: | The micro-thermoelectric-generator based on catalytic combustion of hydrogen and oxygen was designed. With the application of general finite reaction rate model in CFD software of FLUENT, the effect of inlet parameters on the highest temperature difference between the hot and cold plate of the generator was studied. Results showed that, the temperature in the heating and cooling channel of the micro-thermoelectric-generator was uniform; with the increasing of inlet reactant temperature, the highest temperature difference increased, but the total efficiency of the generator decreased. Results can be used to the further design and optimization of micro-thermoelectric-generator based on hydrogen catalytic combustion. |
| |
Keywords: | Hydrogen combustion Catalytic coating Thermoelectric Simulation |