珠海发电厂700 MW汽轮发电机组真空系统治理
引用本文:谭金. 珠海发电厂700 MW汽轮发电机组真空系统治理[J]. 湖北电力, 2007, 31(5): 37-38
作者姓名:谭金
作者单位:广东省电力试验研究所,广东,广州,510600
摘    要:通过分析珠海发电厂1号汽轮发电机组真空系统故障发生的原因,采用氦质谱泄漏检漏技术,及时有效地查明机组真空系统漏点位置,消除漏点,保障了机组安全经济运行。

关 键 词:氦质谱  真空  泄漏检测
文章编号:1006-3986(2007)05-0037-02
修稿时间:2007-03-14

Vacuum System Treatment for 700 MW Turbo Generator Set in Zhuhai Power Plant
TAN Jin. Vacuum System Treatment for 700 MW Turbo Generator Set in Zhuhai Power Plant[J]. Hubei Electric Power, 2007, 31(5): 37-38
Authors:TAN Jin
Affiliation:Guangdong Power Testing and Research Institute, Guangzhou 510600, China
Abstract:By analyzing the cause of the vacuum system failure of No.1 turbo generator set in Zhuhai power plant,the helium mass spectrum leakage detecting technology was adopted.Its leakage point was found out promptly and effectively and the trouble of leakage was cheared.It ensured the units safe economic operstion.
Keywords:helium mass spectrum  vacuum  leak detection