Absolute radiometric calibration of CBERS-02 IRMSS thermal band |
| |
作者单位: | ZHANG Yong1,2,3,GU Xingfa1,3,4,YU Tao1,3,ZHANG Yuxiang5,CHEN Liangfu1,3,LI Xiaoying1,2,3,LI Xiaowen1,3 & HE Liming6 1. State Key Laboratory of Remote Sensing Science,Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University,Beijing 100101,China; 2. Graduate University of Chinese Academy of Sciences,Beijing 100039,China; 3. The Center for National Spaceborne Demonstration,Beijing 100101,China; 4. Institut National de la Recherche Agronomique,Climat Sol Environnement,84914 Avignon,France; 5. National Satellite Meteorological Center,Beijing 100081,China; 6. State Environmental Protection Administration,Beijing 100029,China |
| |
摘 要: | ![]() The China-Brazil Earth Resources Satellite (CBERS) was jointly developed by China and Brazil since 1988. The first CBERS (CBRES-01) was successfully launched on Oc- tober 14, 1999 and the second one (CBERS-02) on October 21, 2003. After finishing on-orbit tests of CBERS-02 in China, it was relegated to China Center for Resources Satellite Data and Applications (CRESDA) and switched to application and routine op- eration stage since January 2004. There are three sensors on C…
|
Absolute radiometric calibration of CBERS-02 IRMSS thermal band |
| |
Abstract: | ![]()
|
| |
Keywords: | CBERS-02 IRMSS thermal band in-flight field calibration onboard blackbody calibration cross calibration. |