摘    要:贵溪电厂有4台SG420t/h型煤粉炉,其中3台炉的水冷壁发生了高温腐蚀。通过宏观,金相显微镜、能谱分析、X射线衍射检测分析以及化学实验等方法,得出了管壁减薄是发生了严重的硫化物型腐蚀的结论,并分析了腐蚀原因。

关 键 词:水冷壁  高温腐蚀  附着物  硫化  锅炉
文章编号:1006-6519(2000)04-0017-03

Analysis of High Temperature Corrosion of Water Wall Tube in SG420 t/h Boiler
PENG Guo-da.Analysis of High Temperature Corrosion of Water Wall Tube in SG420 t/h Boiler[J].Central China Electric Power,2000,13(4):17-19.
Authors:PENG Guo-da
Affiliation:PENG Guo-da ;(Guixi Thermal Power Plant,Jiangxi Province 335400,China)
Abstract:In Guixi Thermal Power Plant, there are four SG420 t/h pulvrized coal-fired boilers, three of which are suffering from high temperature corrosion of water wall tube.By means of macro-examine, optical microscope, EDX, X-ray diffraction and chemical experiment,the conclusion is drawn that tube thickness thinning is caused by severe sulfidation.Causes of corrosion are also discussed.
Keywords:water wall tube  high temperature corrosion  deposit  sulfidation