首页 | 本学科首页   官方微博 | 高级检索  
     


A dose index as a tool to estimate paediatric patient doses in digital projection radiography
Authors:Garcia Castañon Paula  España Lopez Maria Luisa  Fernandez Bedoya Virginia  Bermudez Luna Rocio  Rodriguez Martin Gabriel
Affiliation:Medical Physics and Radiation Protection Department, Hospital Universitario La Princesa, Diego de Leon 62, 28006 Madrid, Spain. pgarciac.hlpr@salud.madrid.org
Abstract:
Radiation exposure during childhood is estimated to have a lifetime risk up to seven times greater than exposures at adult age. Therefore, paediatric patient dose monitoring is a major concern in radiology. The aim of this study is to evaluate the validity of a dose index, displayed at the digital imaging and communication in medicine (DICOM) header of the images, as a dosimetric quantity to estimate the entrance surface dose (ESD) for each procedure. It was carried out over a sample of 156 paediatric patients who underwent a chest examination. National Radiation Protection Board Report 318 model was used to categorise patients by age and to estimate their thickness. Corrected dose index values were compared with calculated ESD, estimated from tube output and radiographic technique. The deviation between both values remained within 2% for every age group, except for patients up to 1 y. Therefore, the index could be used to estimate ESD, allowing to manage greater patient dose databases.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏