首页 | 本学科首页   官方微博 | 高级检索  
     

温度对整辊内嵌式板形检测辊过盈配合的影响
引用本文:吴海淼,刘宏民,于丙强,杨利坡.温度对整辊内嵌式板形检测辊过盈配合的影响[J].钢铁,2016,51(8):55-59.
作者姓名:吴海淼  刘宏民  于丙强  杨利坡
作者单位:1. 河北工程大学机电学院,河北 邯郸 056038 2. 燕山大学国家冷轧板带装备及工艺工程技术研究中心,河北 秦皇岛 066004
基金项目:国家科技支撑计划资助项目(2011BAF15B00);河北省自然科学基金钢铁联合基金资助项目(E2014402055)
摘    要: 在用整辊内嵌式板形检测辊检测可逆冷轧生产过程中带钢的在线板形状况时,板形检测辊的热变形影响辊体内孔面与传感器顶部间过盈配合面的接触状况,引起板形检测信号的间断消失。以整辊内嵌式板形检测辊为研究对象,应用有限元技术对冷轧可逆轧制各道次中检测辊辊体内孔面与骨架顶部过盈配合面各节点副的温度差值、径向相对位移进行模拟分析,获取温度差值对各节点副相对位移和传感器预压力的影响规律。分析结果表明,第3道次各节点副的温度差值最大,大部分节点副的径向相对位移超过配合过盈量,使得传感器预压力接近零,严重影响带钢作用在辊体表面的压力传递,容易造成板形检测信号的中断。

关 键 词:可逆轧制  检测辊  过盈配合  温度  预压力  有限元  
收稿时间:2015-12-06

Influence of temperature on interference fit of entire roller embedded shapemeter roll
WU Hai-miao,LIU Hong-min,YU Bing-qiang,YANG Li-po.Influence of temperature on interference fit of entire roller embedded shapemeter roll[J].Iron & Steel,2016,51(8):55-59.
Authors:WU Hai-miao  LIU Hong-min  YU Bing-qiang  YANG Li-po
Affiliation:(1. College of Mechanical and Electrical Engineering,Hebei University of Engineering,Handan 056038,Hebei,China 2. National Engineering Research Center for Equipment and Technology of Cold Strip Rolling,Yanshan University,Qinhuangdao 066004,Hebei,China)
Abstract:In the process of cold reversible strip flatness detected by entire roller embedded shapemeter roll,the contact condition of interference fit surface between the top surface of framework and the inner hole surface of roll body is af-fected by thermal deformation,so the cold strip flatness detection signal may be interrupted or even disappeared. For en-tire roller embedded shapemeter roll,the temperature differences and radial relative displacements of contact node pairs on the interference fit surface between the top surface of framework and the inner hole surface of roll body,were ana-lyzed using the finite element technology in cold reversible rolling passes. The influences of temperature differences on radius relative displacements of the contact node pairs and the sensor pre-pressure were obtained. The results show that the maximum temperature difference of the contact node pair occurs in the third rolling pass,and most of radial relative displacements of contact node pairs exceed the value of interference fit,which makes the sensor pre-pressure be close to zero. So the transfer of pressure that the strip applied on the outer surface of shapemeter roll is seriously affected,and the shape measuring signal is interrupted.
Keywords:reversible rolling  shapemeter roll  interference fit  temperature  finite element
本文献已被 万方数据 等数据库收录!
点击此处可从《钢铁》浏览原始摘要信息
点击此处可从《钢铁》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号