Abstract: | Decay heat removal capability under boiling condition was studied using an LMFBR fuel subassembly mockup loop. The sodium flow was driven by natural convection through the loop in which was installed a 37-pin bundle heated electrically over a length of 45 cm. The heat flux furnished by the pins was increased stepwise, upon which the two-phase flow regime changed from bubble to slug flow and then to annular or annular mist flow. Dryout occurred even in slug flow regime, but only momentarily, and permanent dryout was not observed before establichment of annular flow. A suitable criterion for permanent dryout is considered to be 0.5 average exit sodium vapor quality. The results indicated that upon occurrence of sodium boiling, the coolability of fuel subassembly would be maintained by natural convection after reactor shutdown. |