首页 | 本学科首页   官方微博 | 高级检索  
     


Control of power factor correcting boost converter withoutinstantaneous measurement of input current
Authors:Sivakumar  S Natarajan  K Gudelewicz  R
Affiliation:Res. & Dev., KB Electron. Ltd., Bedford, NS ;
Abstract:This paper proposes a new control method for the constant-frequency control of power factor correcting boost power converter using a sinewave template modulated PWM signal which eliminates the need for instantaneous measurement of the line current for the switching control of the boost converter. The control strategy is based on the notion that the line current can be forced to trace a deterministic waveform such as a sinusoid by considering the implicit model of the sinewave in the boost converter controller structure. The modulating sinewave template is generated using the line voltage, the boost converter output voltage and the load current. The paper provides the analysis and the design of the controller and presents simulation and implementation results to demonstrate its effectiveness
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏