首页 | 本学科首页   官方微博 | 高级检索  
     

用交流电压进行高压XLPE绝缘电缆线路的现场试验
引用本文:万树德. 用交流电压进行高压XLPE绝缘电缆线路的现场试验[J]. 广东电力, 1999, 12(3): 44-46
作者姓名:万树德
作者单位:上海电缆研究所
摘    要:根据XLPE绝缘电缆用直流电压进行现场试验的经验,要求开发新的方法。现在有一种移动式调频串联揩振装置能够用交流电压进行试验,这意味着适用于塑料绝缘电缆敷设后的试验将有重大突破。配有经由户外户内开关设备而接至电缆线路的连接线,以满足不同用户的要求。

关 键 词:高压电缆 交联聚乙烯绝缘电缆 现场试验 油浸纸绝缘电力电缆 交流电压

Field tests of XLPE insulated high voltage cable systems with AC voltage
WAN Shu de. Field tests of XLPE insulated high voltage cable systems with AC voltage[J]. Guangdong Electric Power, 1999, 12(3): 44-46
Authors:WAN Shu de
Abstract:There exist major defects in conventional site tests of XLPE insulated cables with DC voltage,therefore,a new method with better testing results must be found.The mobile frequency modulation series resonant tester has been developed to conduct the said tests with AC voltage,which can be connected,through connecting wires,to cable system via outdoor or indoor switchgears and satisfy demands of different customers.
Keywords:HV cable  XLPE insulated cable  field test  testing method  frequency modulation series resonant tester
本文献已被 CNKI 维普 等数据库收录!