首页 | 本学科首页   官方微博 | 高级检索  
     


Full Automated Synthesis of18F-FDOPA and Preliminary PET/CT Imaging
Authors:WEN Fuhua  ZHANG Zhanwen  Ma Hui  ZHANG Dake  TANG Ganghua
Affiliation:Department of Nuclear Medicine, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510080, China
Abstract:18F-fluoro-L-dihydroxyphenylalanine (18F-FDOPA) as a dopamine neurotransmitter imaging agent has been widely used for diagnosis and therapy evaluation of Parkinson's disease, brain tumors and neuroendocrine diseases with positron emission tomography (PET) imaging in clinical setting and research. To meet the increasing clinical demand in oncology and neurology, a routine protocol for the automated synthesis of18F-FDOPA with a disposable cassette system on an imported multifunctional synthesizer was studied and discussed.18F-FDOPA was automatically synthesized via a multiple-step reaction, including fluorination, reduction, iodization alkylation and hydrolysis, following purification by using a semi-preparative high-performance liquid chromatography (HPLC) system which was built in the multifunctional synthesizer. After HPLC purification, the purified18F-FDOPA solution was collected and passed through a sterilizing filter into a collection bottle. The final18F-FDOPA injection was obtained for quality control (QC) determination. The QC indexes of the final products were detected: the injection was colorless and transparent, pH value was at 4 to 5.5, radiochemical purity >98%, radionuclide purity >99%, specific activity >1.9 GBq/μmol, K2.2.2 content <50 mg/L, methanol content <0.01%, alcohol content <0.01%, dichloromethane content <0.01 mg/L, dimethylformamide content <15 mg/L, bacterial endotoxin test <0.100 EU/mL, sterility test 0 cfu/mL,and abnormal toxicity test was negative. PET/CT imaging of rats was performed by intravenous injection of18F-FDOPA half an hour after the intraperitoneal injection of carbidopa, PET/CT scan was performed after 100 min post-injection. The imaging of18F-FDOPA showed symmetry high uptake in the bilateral striatum of normal rats. The decay-corrected radiochemical yield of18F-FDOPA from the18F-fluoride was (63.1±3.8)% (n=10) at the end of synthesis (EOS), the radiochemical purity was no less than 98%, and the total radiosynthesis time was within 80 min. The quality control results demonstrated that the quality indexes of the final injection solution met the relevant requirements of radiopharmaceutlcals, which were well-suited for clinical application. An efficient and high reproducible automatic method for the radiosynthesis of18F-FDOPA with high radiochemical yields and good radiochemical purity is obtained and performed via a multi-step reaction on the multifunctional synthesizer.18F-FDOPA can be used for animal and human PET imaging.
Keywords:multifunctional synthesizer  18F-FDOPA  microPET/CT imaging  
点击此处可从《同位素》浏览原始摘要信息
点击此处可从《同位素》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号