首页 | 本学科首页   官方微博 | 高级检索  
     


Quantitative measurement of gas hold-up distribution in a stirred chemical reactor using X-ray cone-beam computed tomography
Authors:Stephan Boden  Martina Bieberle  Uwe Hampel
Affiliation:

aForschungszentrum Dresden-Rossendorf e.V., Institute of Safety Research, P.O. Box 510119, 01314 Dresden, Germany

Abstract:Cone-beam type X-ray computed tomography (CBCT) is a potential method to measure three-dimensional phase distributions in vessels. An example for that is the measurement of gas profiles in stirred chemical reactors. Such data are highly valuable for the assessment and evaluation of chemical processes, for optimisation of the reactor and stirrer design, and for evaluation of computational fluid dynamics codes used to model the fluid flow and heat transfer in reactive systems. However, there are considerable difficulties for accurate quantitative measurements due to beam hardening and radiation scattering effects. In a theoretical and experimental work we have investigated the non-linear effects of both physical phenomena and developed a suitable measurement setup as well as calibration and software correction methods to achieve a highly accurate measurement of void fraction profiles with CBCT.
Keywords:Cone-beam computed tomography  Gas hold-up measurement  Chemical reactor
本文献已被 ScienceDirect 等数据库收录!