Apparatus for isochoric specific heat capacity measurement
Quan ZHONG,Xueqiang DONG,Yanxing ZHAO,Jingzhou WANG,Haiyang ZHANG,Jun SHEN,Maoqiong GONG.Apparatus for isochoric specific heat capacity measurement[J].Journal of Chemical Industry and Engineering(China),2019,70(z2):20-24.
Authors:Quan ZHONG  Xueqiang DONG  Yanxing ZHAO  Jingzhou WANG  Haiyang ZHANG  Jun SHEN  Maoqiong GONG
Affiliation:1. Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China2. University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:As one of the most important thermodynamic properties, isochoric specific heat capacity is related to the calculation of internal energy and entropy, is the key parameter of engineering design. What is more, isochoric specific heat capacity is derived by the second derivative of pressure with respect to temperature and is important for verifying the accuracy of equation of state. An adiabatic calorimeter was developed to measure the isochoric specific heat capacity. A spherical bomb with platinum resistance thermometer inserted was used to hold the measured liquid. The cooling capacity was provided by a mixed-refrigerant Joule-Thomson refrigerator. In view of the difficult problem of heat insulation in a wide temperature range, two adiabatic shields were arranged and the PID temperature control method was designed independently to reduce the temperature difference between the bomb and the adiabatic shield. The temperature difference between the bomb and the inner adiabatic shield was less than 0.2 K throughout the experiment. In order to verify the reliability of the experimental setup, the isochoric specific heat capacity data of isobutane were measured over temperatures from 279.10 K to 323.68 K. Satisfactory agreement with published heat capacity data is found and the average absolute relative deviation between this data and the values calculated from REFPROP 9.1 is 0.88%.
Keywords:isochoric specific heat capacity  thermodynamic property  adiabatic calorimeter  radiation  isobutane  compressed liquid  equation of state  