首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of RF Transmission Mode in ITER Relevant EC H&;CD Transmission Line
Authors:Yasuhisa Oda  Ken Kajiwara  Koji Takahashi  Atsushi Kasugai  Michael A Shapiro  Richard J Temkin  Keishi Sakamoto
Affiliation:(1) Plasma Heating Research Group, Japan Atomic Energy Agency, Naka Fusion Research Institute, 801-1 Mukoyama, Naka, Japan;(2) Plasma Science and Fusion Center, Massachusetts Institute of Technology, 167 Albany St., Cambridge, MA, USA
Abstract:The preliminary results of mode measurement in the ITER relevant 40 m long transmission test line composed from 63.5 mm diameter corrugated waveguides and miter bends are presented. The field patterns were measured by taking temperature profiles on a paper screen placed in front of the waveguide end using an infrared imaging camera. The complex electric field at the waveguide end was retrieved from the measured temperature profiles. As a result, the transmission power includes 87% of HE11 mode and 6% of LP11 odd (HE21+TE01) mode and small ratios of other modes. The mode content had small dependence on length of the transmission line. This result indicated that the higher order mode content generated at the input of the transmission line is conserved and propagated through the transmission line. This suggests that the initial RF coupling to the waveguide is critical since it affects the launcher efficiency.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号