首页 | 本学科首页   官方微博 | 高级检索  
     

NG-220/9.8-M24型循环流化床锅炉水冷壁磨损及处理
引用本文:翁志雄.NG-220/9.8-M24型循环流化床锅炉水冷壁磨损及处理[J].黑龙江电力,2009,31(2):117-119.
作者姓名:翁志雄
作者单位:福建省厦门电厂检修事业部,福建,厦门,361022
摘    要:阐述了厦门瑞新热电厂(厦门电厂技改扩建项目)循环流化床锅炉水冷壁管易磨损部位,对磨损原因进行了分析,采取了相应的处理措施,有利于减少水冷壁磨损事故发生。

关 键 词:循环流化床锅炉  水冷壁  磨损  处理

Water wall abrasion and treatment of NG-220/9.8-M24 type CFB boiler
WENG Zhixiong.Water wall abrasion and treatment of NG-220/9.8-M24 type CFB boiler[J].Heilongjiang Electric Power,2009,31(2):117-119.
Authors:WENG Zhixiong
Affiliation:Xiamen Electric Power Plant of Fujian Province;Xiamen 361022;China
Abstract:The paper introduced to the position of water-cooled wall tubes abrasion of CFB boiler for Xiamen Ruixin Thermal Power Plant and analyzed its reasons.Some measures were suggested to decrease the abrasion trouble.
Keywords:circulating fluidized bed (CFB) boiler  water - cooled wail  abrasion  treatment