首页 | 本学科首页   官方微博 | 高级检索  
     


Gamma-ray response function of some polymeric nuclear track detectors
Authors:A. Hussein  Kh. Shnishin  A. A. Abou El -Kheir
Affiliation:(1) Physics Department, Faculty of Science, El-Monoufia University, Shebin El-Koam, Egypt;(2) Physics Department, Faculty of Science, Alexandria University, Alexandria, Egypt
Abstract:The effect of gamma dose on the bulk-etch rate measurements for some gamma-irradiated polymeric nuclear track detectors was extensively studied. Various plastic samples of CR-39 allyl diglycol carbonate, Makrofol-E and Lexan polycarbonates were used and exposed to gamma doses up to 30.0 Mrad. The bulk-etch rate ratioV BD/V BO, i.e. the bulk-etch rate of irradiated samples to the unirradiated ones, was measured at the most recommended optimum etching conditions. Fading behaviour of irradiated CR-39 samples was also studied at room temperature and for a duration of up to 8 days. It was found that the etch-rate ratio for the CR-39 specimens was dose-dependent. In contrast, the polycarbonate samples showed an extremely weak response to gamma irradiation. The results of the present work reflected great evidence of the gamma dosimetric potential of CR-39 plastic detectors, which can indeed be recommended as gamma-dosimeters within the studied dose range.