首页 | 本学科首页   官方微博 | 高级检索  
     


Rapid detection of Campylobacter jejuni in chicken rinse water by melting-peak analysis of amplicons in real-time polymerase chain reaction
Authors:Cheng Zhihui  Griffiths Mansel W
Affiliation:Department of Food Science, University of Guelph, 43 McGilvray Street, Guelph, Ontario, Canada N1G 2W1.
Abstract:Five DNA extraction protocols for the detection of Campylobacter spp. by polymerase chain reaction (PCR) were compared. A method involving Triton X-100 produced template DNA of sufficient quality to allow the detection of Campylobacter jejuni at levels of 100 CFU/ml in pure culture. Primers were designed on the basis of the cadF gene sequence. With a SYBR Green I real-time PCR assay, these primers amplified only sequences present in C. jejuni to produce a product with a melting temperature of 81.5 degrees C. None of the strains of Campylobacter coli, Campylobacter lari, or Campylobacter fetus tested produced this product during the PCR assay. Other noncampylobacter species tested were shown not to possess the cadF sequence. The real-time PCR combined with a rapid, simple Triton X-100 DNA extraction protocol made it possible to detect < 10 CFU of C. jejuni per ml of chicken rinse within 14 h.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏