首页 | 本学科首页   官方微博 | 高级检索  
     


A new architecture for non-linear analogue-digital conversion
Authors:V. P. SUNDARSINGH
Affiliation:Department of Electrical Engineering , Indian Institute of Technology , Bombay, 400 076, India
Abstract:A modified architecture is proposed for the non-linear analogue-digital conversion of a transducer response. It is proved that by making use of a dual-slope A/D converter and by changing the clock frequency fed to the A/D converter during the deintegration period and blocking some of the pulses during this period, a nonlinear A/D conversion can be achieved. This method was used to linearize a Pt-PtRh thermocouple response and excellent results were obtained. Further, it is proved that the frequency change depends only on the maximum slope of the transducer response that is to be corrected.