摘    要:某商厦由于遭受火灾,导致结构出现较大损失。为了消除安全隐患,需要对该商厦进行全面的安全性检测鉴定。通过现场勘察推定火灾的主要作用区域、火场区域温度,根据灾后结构损伤现状评定构件损伤状态等级。依据现场检测鉴定结果,分析验算结构或构件过火后剩余承载能力,为后续的加固处理方案提供依据。

关 键 词:火灾  安全性鉴定  损伤等级  剩余承载力

Safety assessment of a commercial building after the fire hazard
Abstract:A commercial building has been suffered great damage after a fire hazard.In order to eliminate the hidden danger of the struc-ture, the safety detection and assessment were taken.Fire area and temperature distribution of the fire were deduced by site survey , the damage level of the structural components were evaluated.Based on the result , the structural residual load -carrying capacity was ana-lyzed and provided the basis for the following reinforcement scheme.