首页 | 本学科首页   官方微博 | 高级检索  
     

双锥腔互补偿型绝对辐射计
引用本文:王玉鹏,方伟,弓成虎,禹秉熙.双锥腔互补偿型绝对辐射计[J].光学精密工程,2007,15(11):1662-1667.
作者姓名:王玉鹏  方伟  弓成虎  禹秉熙
作者单位:1. 中国科学院,长春光学精密机械与物理研究所,应用光学国家重点实验室,吉林,长春,130033;中国科学院,研究生院,北京,100039
2. 中国科学院,长春光学精密机械与物理研究所,应用光学国家重点实验室,吉林,长春,130033
摘    要:介绍了一种双锥腔互为补偿的新型绝对辐射计(DCICAR)。采用和导热帽檐一体成型的锥腔,微型铂电阻作温度传感器,双锥腔肩并肩放置,面对相同的视场和热环境,且一直维持相同的温度,传导、对流和热耗散情况相同,以互为补偿方式工作。测量结果表明:测量重复性可达0.05%,用参加2005年在世界辐射中心(WRC)举办的第十届国际日射计比对IPC-X的SIAR-2c作为传递基准,本文研制的DCICAR的A#通道相对世界辐射参考(WRR)的校正因子为0.999 73,B#通道的校正因子为0.999 17,均与WRR在0.1%以内相符。该仪器提高了双腔补偿效果,且灵敏度高,时间常数小,双腔测量结果可相互比对验证,降低了绝对辐射计的测量不确定度。

关 键 词:辐射测量  双锥腔互补偿  绝对辐射计  比对
文章编号:1004-924X(2007)11-1662-06
收稿时间:2007-08-21
修稿时间:2007-08-21

Dual cavity inter-compensating absolute radiometer
WANG Yu-peng,FANG Wei,GONG Cheng-hu,YU Bing-xi.Dual cavity inter-compensating absolute radiometer[J].Optics and Precision Engineering,2007,15(11):1662-1667.
Authors:WANG Yu-peng  FANG Wei  GONG Cheng-hu  YU Bing-xi
Affiliation:1. State Key Laboratory of Applied 0ptics ,Changchun Institute of 0ptics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033 ,China;2. Graduate School of the Chinese Academy of Sciences ,Beijing 100039 ,China
Abstract:A new type absolute radiometer, named Dual Cavity Inter-Compensating Absolute Radiometer(DCICAR)was constructed. A conical cavity of DCICAR is fabricated as a whole body by combined the conical part with the cap brim for heat conduct and a Pt resistance is used as temperature sensor. The DCICAR works in a mode of inter-compensated when the two cavities are put side by side and faced the same field of view(FOV), also kept the same states of heat conducting,convection,dissipation and heat sink in the same temperature environment. The two cavities are always heated in the same temperature through the whole measurement process. Experimental results show that the repetition of DCICAR is better than 0.05%. By taking the SIAR-2c (Solar Irradiance Absolute Radiometer) as transfer standard demonstrated in the Tenth International Pyrheliometer Comparisons (IPC-X) organized by World Radiation Center (WRC) at Switzerland in 2005, the correct factor of channel A of DCICAR relatively to World Radiation Reference(WRR) is 0.999 73, and the channel B of 0.999 17. So DCICAR can be well coincident with WRR in 0.1%.It concludes that the compensation effect of DCICAR is improved with a short time constant and high sensitivity. The measurement results from two cavities could be compared and validated with each other.
Keywords:radiation measurement  Dual Cavity Inter-Compensation(DCIC)  absolute radiometer  comparison
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号