Nondestructive Evaluation of Fiberglass Wrapped Concrete Bridge Columns |
| |
Authors: | Kyu-Sun Kim Dante Fratta José A Pincheira |
| |
Affiliation: | (1) Department of Civil Engineering, Jordan University of Science and Technology, P.O. Box 3030, Irbid, 22110, Jordan;(2) Department of Civil Engineering, Hadramout University of Science and Technology, P.O. Box 50512-50511, Mukalla, Yemen |
| |
Abstract: | Many in-service concrete bridge decks and columns built before the advent of epoxy coated bars show cracking and spalling
of the concrete due to corrosion of the steel reinforcement. In cold regions, the corrosion rate of concrete bridge decks
and columns is accelerated by the use of deicing solutions in winter. The corrosion of the steel rebars causes cracking, delamination,
and spalling of reinforced concrete structures and increases the cost of rehabilitation and maintenance operations. In Wisconsin
(USA), fiberglass wrapping has been used for corrosion protection of reinforced concrete columns. In this methodology, a fiberglass
wrap is placed as a barrier between the concrete surface and the surrounding environment and is expected to reduce the detrimental
effect of traffic splashing of deicing solutions. This paper describes a study aimed at evaluating the effectiveness of fiberglass
wrapping in controlling and reducing the rate of corrosion in bridge concrete columns. Field tests included nondestructive
wave propagation and half-cell potential methods. Nondestructive evaluation results were examined and compared to chloride
ion (Cl−) intrusion measurements. The data show that fiberglass wrapping helps in arresting the chloride ion ingress to the columns,
however, it does not help reduce corrosion rates in chloride contaminated concrete columns. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|