首页 | 本学科首页   官方微博 | 高级检索  
     


On-line monitoring of fuel moisture-content in biomass-fired furnaces by measuring relative humidity of the flue gases
Authors:Sven Hermansson  Fredrik Lind  Henrik Thunman
Affiliation:1. L2CSP Laboratoire de Conception et de conduite de Systèmes de Production, University of Tizi Ouzou, Algeria;2. IRIT-ENSEEIHT, University of Toulouse, France;3. LAPLACE-ENSEEIHT, University of Toulouse, France
Abstract:Combustion of biomass for heat and power production is continuously growing in importance, because of incentives for replacing fossil energy resources with renewable ones. In biomass combustion, the moisture content of the fuel is an essential operation parameter, which often fluctuates for biomass fuels. Variation in moisture content complicates the operation of the furnaces and results in an uncertainty in the energy content of the fuel delivered to a plant. The fuel moisture-content in a furnace may be determined either by direct measurement on the entering fuel or by measuring the moisture and oxygen contents of the flue gases deriving the moisture content of the fuel. However, reliable methods of a motivated cost for the small to medium-scale furnaces are today not available. An exception is if the furnace is equipped with flue-gas condenser, which can be used to estimate the moisture content of the flue gases. A limitation of this method is, though, that not all furnaces have flue-gas condensers and that the measured signal has an inherent time delay.In this work, measurement of the relative humidity (RH) of the flue gases from a furnace is investigated as the central component in the on-line monitoring of the moisture content of the fuel in a furnace. The method was analysed with humid air in a laboratory environment and tested for accuracy and dynamical behaviour in two biomass-fired heat-production units, one circulating fluidised-bed boiler (CFB) and one grate furnace. The results show that the method, which is easy to calibrate on site, can be used to predict the moisture content of the biomass fuel in the grate furnace with very good precision (<4% error). Furthermore, the method detects variations in moisture content of the furnace flue gases due to changes in the moisture content of the combusted fuel within the order of seconds. Since the transport time of the flue gases from the furnace to the measurement position is of the same order of magnitude, the total time for detection of a change in the moisture content of the fuel is small enough for the signal to be used to control both the fuel feed and the combustion air in a grate furnace.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号