Development of a prototype tapered cell drift chamber |
| |
Authors: | J.A. Blissett D.K. Hasell E.W. Kendall B.T. Payne D.H. Saxon |
| |
Affiliation: | Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX, England |
| |
Abstract: | Drift chamber cells have been constructed and tested using an electron test beam facility at DESY. The cells were operated under different voltage conditions and with different gas mixtures at 1 bar. Aspects of the construction and operation are discussed. Resolutions were typically less than 100 μm. The dependence of the drift cell resolution on distance from the sense wire and operating conditions are presented. |
| |
Keywords: | |