High precision frequency measurement based on the characteristic of the fuzzy area
Authors:JIA Zhaomin  LI Zhiqi  ZHOU Wei  YANG Xuhai  SUN Baoqi  MIAO Miao  DONG Shaofeng
Affiliation:(1. National Time Service Centre, Chinese Academy of Sciences, Xi 'an 710600, China; 2. Univ. of Chinese Academy of Sciences, Beijing 100049, China; 3. Intelligence and Information Engineering College, Tangshan Univ., Tangshan 063020, China; 4. School of Mechano-electronic Engineering, Xidian Univ., Xi'an 710071, China)
Abstract:The phase difference change is random in the discrete fuzzy area by considering the limit of device resolution, which the device can not stably capture, and the precision of the measured value only reaches the level of ns, but the phase difference change in the concentrated fuzzy area is step by step, and the device can stably capture the change of ps. By using the fuzzy area conversion technology, a high precision frequency measurement is designed. Through computer control and frequency synthesis,the discrete fuzzy area is converted to the concentrated fuzzy area, the ps stability properties of phase difference change on the border of the concentrated fuzzy area is used, the precision can be improved two or three orders of magnitude, and the high precision measurement in a wide range is achieved.
Keywords:frequency measurement  phase difference change  measurement resolution  fuzzy area  
点击此处可从《西安电子科技大学学报》浏览原始摘要信息