首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of ambient humidity and temperature on partial discharge characteristics of conventional and nanocomposite enameled magnet wires
Abstract:Effects of ambient humidity and temperature on partial discharge (PD) characteristics in twisted pairs with conventional and nanocomposite enameled magnet wires have been investigated. Measurements of the PD inception voltage (PDIV) and the apparent PD charge were performed by applying an ac sinusoidal waveform voltage of 60 Hz to the twisted pair. The observed PDIV in this study can be classified into the following three behaviors. First, the PDIV in both wires decreases with increasing relative humidity (RH) at low temperature. Secondly, the PDIV in both wires slightly increases when increasing the RH at high temperature. Thus, there is a certain value of the absolute humidity to determine the lowest PDIV in both cases with the conventional and nanocomposite enameled wires. Thirdly, the PDIV in the conventional enameled wire significantly decreases at the RH of 95 %, while the decrease rate of that in the nanocomposite enameled wire is relatively small. The observed PD phenomena are discussed in terms of material characterization of the enameled wires such as changes in permittivity due to moisture absorption and wettabilitiy under voltage application.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号