首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of bulk lubricant concentration on the excess surface density during R123 pool boiling
Authors:M A Kedzierski  
Affiliation:

National Institute of Standards and Technology, Building 226, Room B114, Gaithersburg, MD 20899, USA

Abstract:This paper investigates the effect that bulk lubricant concentration has on the non-adiabatic lubricant excess surface density on a roughened, horizontal flat (plain) pool-boiling surface. Both pool boiling heat transfer data and lubricant excess surface density data are given for pure R123 and three different mixtures of R123 and a naphthenic mineral oil. A spectrofluorometer was used to measure the lubricant excess density that was established by the boiling of a R123/lubricant mixture on a test surface. The fluorescent technique was used to measure the effect of bulk lubricant concentration on the lubricant excess layer during refrigerant/lubricant mixture boiling. The refrigerant preferentially boils, thus, concentrating and accumulating the lubricant on the surface in excess of the bulk concentration. The excess lubricant resides in a very thin layer on the surface and influences the boiling performance. Accordingly, the ability to measure the effect of bulk lubricant composition on the lubricant excess density and in turn the effect on the heat transfer would lead to a fundamental understanding of the mechanism by which lubricants can degrade or improve boiling performance. In support of this effort, heat transfer data are provided for pure R123 and three R123/lubricant mixtures at 277.6 K. For heat fluxes between approximately 25 to 45 kW/m2, an average enhancement of the heat flux of 9 and 5% was achieved for the 0.5 and 1% lubricant mass fractions, respectively, and an average degradation of 5% in the heat flux was obtained for the 1.8% lubricant mass fraction mixture.

Résumé

This paper investigates the effect that bulk lubricant concentration has on the non-adiabatic lubricant excess surface density on a roughened, horizontal flat (plain) pool-boiling surface. Both pool boiling heat transfer data and lubricant excess surface density data are given for pure R123 and three different mixtures of R123 and a naphthenic mineral oil. A spectrofluorometer was used to measure the lubricant excess density that was established by the boiling of a R123/lubricant mixture on a test surface. The fluorescent technique was used to measure the effect of bulk lubricant concentration on the lubricant excess layer during refrigerant/lubricant mixture boiling. The refrigerant preferentially boils, thus, concentrating and accumulating the lubricant on the surface in excess of the bulk concentration. The excess lubricant resides in a very thin layer on the surface and influences the boiling performance. Accordingly, the ability to measure the effect of bulk lubricant composition on the lubricant excess density and in turn the effect on the heat transfer would lead to a fundamental understanding of the mechanism by which lubricants can degrade or improve boiling performance. In support of this effort, heat transfer data are provided for pure R123 and three R123/lubricant mixtures at 277.6 K. For heat fluxes between approximately 25 kW/m2 to 45 kW/m2, an average enhancement of the heat flux of 9% and 5% was achieved for the 0.5% and 1% lubricant mass fractions, respectively, and an average degradation of 5% in the heat flux was obtained for the 1.8% lubricant mass fraction mixture.

Keywords:Heat transfer  Mass transfer  Pool boiling  Mixture  Lubricant  Concentration  Density  SurfaceAuthor Keywords: Transfert de chaleur  Transfert de masse  Ébullition libre  Mélange  Lubrifiant  Concentration  Densité  Surface
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号