首页 | 本学科首页   官方微博 | 高级检索  
     


Tap water quality and performance of point-of-use treatment devices in Cairo, Egypt
Authors:Edward Smith,&   Sally El Komos
Affiliation:Environmental Engineering Program, The American University in Cairo, Cairo, Egypt and;Komex Environmental Services, Cairo, Egypt
Abstract:Tap water quality was examined in six sampling events over a 2-year period in a residential community of Greater Cairo, Egypt. The sampling sites chosen had a granular activated carbon (GAC), reverse osmosis (RO) or distillation point-of-use (POU) treatment device so that the performance of these units for standard water quality parameters could be evaluated. Tap water satisfied Egyptian and international drinking water standards and guidelines for the majority of samples analysed. Exceptions were the violation of international limits for lead in 10 samples, and total trihalomethane (TTHM) levels that occasionally exceeded drinking water limits. Only the RO and distillation units achieved removal of total dissolved solids (TDS), alkalinity and hardness. However, GAC units are considerably less costly in the local market. All three POU units exhibited potential reduction of chemical contaminants such as trihalomethanes (THMs), improved taste via chlorine removal and improvement in clarity. Realization of these benefits, however, is conditioned upon proper operation and maintenance of the device.
Keywords:distillation    drinking water    granular activated carbon    point-of-use treatment    reverse osmosis    trihalomethanes    water quality
设为首页 | 免责声明 | 关于勤云 | 加入收藏