首页 | 本学科首页   官方微博 | 高级检索  
     

并网逆变器降阶模型及其构建方法的分析与对比
引用本文:于鸿儒,苏建徽,王一丁,汪海宁,施永.并网逆变器降阶模型及其构建方法的分析与对比[J].电力系统自动化,2020,44(10):155-165.
作者姓名:于鸿儒  苏建徽  王一丁  汪海宁  施永
作者单位:光伏系统教育部工程研究中心(合肥工业大学),安徽省合肥市 230009
基金项目:国家重点研发计划资助项目(2018YFB1500802)。
摘    要:并网逆变器的小信号模型是判断系统稳定性和参数设计的重要工具。并网逆变器的完整状态方程描述会附带较多冗余信息,采用适当的降阶模型能够方便系统参数整定与调试。然而现有的一些典型降阶模型适用面较窄,在特定工况下精度较低或随着参数的变化而失去通用性。首先,通过等效惯性常数与等效阻尼系数的概念建立了通用的功率环模型;通过单边傅里叶分析指出传统的三阶模型仅适用于分析大惯性、高阻尼系统;通过输出阻抗分析指出电磁五阶模型精度对于控制参数较为敏感。为了解决降阶模型精度的问题,利用逆变器时间尺度自然分离的特性,提出了一种基于时间常数的模型降阶方法,所提方法简单、有效,并导出了可靠、简洁的高带宽降阶模型,所得模型精度高、适用面广。最后,通过对比实验验证了理论分析的正确性和所提降阶方法与降阶模型的有效性。

关 键 词:降阶模型  稳定性分析  并网逆变器  时间尺度  虚拟同步发电机
收稿时间:2019/10/29 0:00:00
修稿时间:2020/2/4 0:00:00

Analysis and Comparison of Reduced-order Model and Modeling Method for Grid-connected Inverter
YU Hongru,SU Jianhui,WANG Yiding,WANG Haining,SHI Yong.Analysis and Comparison of Reduced-order Model and Modeling Method for Grid-connected Inverter[J].Automation of Electric Power Systems,2020,44(10):155-165.
Authors:YU Hongru  SU Jianhui  WANG Yiding  WANG Haining  SHI Yong
Affiliation:(Research Center for Photovoltaic System Engineering of Ministry of Education (Hefei University of Technology), Hefei 230009, China)
Abstract:The small-signal model of grid-connected inverter is an important tool for judging system stability and parameter design. The complete state equation of the grid-connected inverter will be accompanied by more redundant information. It is convenient to tune and debug system parameters by adopting appropriate reduced-order model. However, some of the existing typical reduced-order models have narrow applicability, low accuracy under specific conditions or loss of generality with the change of parameters. Firstly, this paper develops a general power-loop model based on the concepts of equivalent inertia constant and equivalent damping coefficient. Through single-side Fourier analysis, it is pointed out that the traditional third-order model is only suitable for the analysis of the systems with large inertia and high damping. Through the analysis of output impedance of grid-connected inverter, it is pointed out that the accuracy of the electromagnetic fifth-order model is sensitive to the control parameters. In order to solve the accuracy problem of reduced-order model, a model order-reduction method based on time constant is proposed by using the characteristics of natural separation of the time scale of inverters. The proposed method is simple and effective. And a simple reduced-order model of the inverter is derived. The obtained model has high accuracy and wide application. Finally, the correctness of the theoretical analysis and the effectiveness of the order-reduction method and the reduced-order model are verified by comparative experiments.
Keywords:reduced-order model  stability analysis  grid-connected inverter  time scale  virtual synchronous generator (VSG)
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统自动化》浏览原始摘要信息
点击此处可从《电力系统自动化》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏