首页 | 本学科首页   官方微博 | 高级检索  
     

A Cold Model Aerodynamical Test of Air-Staged Combustion in a Tangential Firing Utility Boiler
作者姓名:ZHANG  Hui-juan  HUI  Shi-en  ZHOU  Qu-lan
作者单位:School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P. R. China
摘    要:The purpose of this paper is to present the flow field in the 300MW tangential firing utility boiler that used the Low NOx Concentric Firing System (LNCFS). Using the method of cold isothermal simulation ensures the geometric and boundary condition similarity. At the same time the condition of self-modeling is met. The experimental results show that the mixture of primary air and secondary air becomes slower, the average turbulence magnitude the relative diameter of the tangential firing enlarges of the main combustion zone becomes less and when the secondary air deflection angle increases When the velocity pressure ratio of the secondary air to the primary air (p2/p1) enlarges, the mixture of the secondary air and the primary air becomes stronger, the average turbulence magnitude of the main combustion zone increases, and the relative diameter of the tangential firing becomes larger. Because the over fire air (OFA) laid out near the wall has a powerful penetration, the relative diameter of the tangential firing on the section of the OFA is very little, but the average turbulence magnitude is great. When the velocity pressure ratio of the OFA to the primary air POFA/p1 increases, the relative diameter of the tangential firing on the section of the OFA grows little, the average turbulence magnitude becomes larger and the penetration of the OFA becomes more powerful.

关 键 词:切向燃烧锅炉  电厂锅炉  冷模型  动力学试验  空气分级燃烧
收稿时间:2006-10-17

A Cold Model Aerodynamical Test of Air-Staged Combustion in a Tangential Firing Utility Boiler
ZHANG Hui-juan HUI Shi-en ZHOU Qu-lan.A Cold Model Aerodynamical Test of Air-Staged Combustion in a Tangential Firing Utility Boiler[J].International Journal of Plant Engineering and Management,2007,12(1):36-41.
Authors:ZHANG Hui-juan  HUI Shi-en  ZHOU Qu-lan
Abstract:The purpose of this paper is to present the flow field in the 300MW tangential firing utility boiler that used the Low NOx Concentric Firing System (LNCFS). Using the method of cold isothermal simulation ensures the geometric and boundary condition similarity. At the same time the condition of self-modeling is met. The experimental results show that the mixture of primary air and secondary air becomes slower, the average turbulence magnitude of the main combustion zone becomes less and the relative diameter of the tangential firing enlarges when the secondary air deflection angle increases. When the velocity pressure ratio of the secondary air to the primary air (p2/p1) enlarges, the mixture of the secondary air and the primary air becomes stronger, the average turbulence magnitude of the main combustion zone increases, and the relative diameter of the tangential firing becomes larger. Because the over fire air (OFA) laid out near the wall has a powerful penetration, the relative diameter of the tangential firing on the section of the OFA is very little, but the average turbulence magnitude is great. When the velocity pressure ratio of the OFA to the primary air pOFA/p1 increases, the relative diameter of the tangential firing on the section of the OFA grows little, the average turbulence magnitude becomes larger and the penetration of the OFA becomes more powerful.
Keywords:air-staged combustion  concentric firing system  cold model
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号