首页 | 本学科首页   官方微博 | 高级检索  
     

隔离电器的选择
引用本文:曲德刚,奚泓,章克强.隔离电器的选择[J].建筑电气,2007,26(12):4-6.
作者姓名:曲德刚  奚泓  章克强
作者单位:上海电器科学研究所(集团)有限公司,上海市,200063
摘    要:隔离电器事关人身安全,必须合理选择与使用。隔离电器应具备三个必要条件(符合动触头在断开位置时的指示要求、应能承受的额定冲击耐受电压值要求和每极进出线端子间允许泄漏电流值要求),才能作为隔离电器使用。还介绍了隔离器和隔离开关的差异和带隔离功能的断路器。

关 键 词:隔离器  隔离开关  断路器  ATSE(自动转换开关电器)

The Selection of Isolating Devices
Qu Degang,Xi Hong,Zhang keqiang.The Selection of Isolating Devices[J].Building Electricity,2007,26(12):4-6.
Authors:Qu Degang  Xi Hong  Zhang keqiang
Abstract:Isolating devices are related to personal safety, which should be rationally selected and utilized. Only when the isolating devices possess three prerequisites, which are the indication requirement of the moving contact at the off position, the requirement of the rated impulse withstand voltage to be endured and the requirement of allowable leakage current values between lead-in and out terminals of each electrode, can they be used as isolating devices. Moreover,in this paper,the difference between disconnector and switch-disconnector,the circuit breaker with isolation function are introduced.
Keywords:Disconnector Switch-disconnector Circuit breaker ATSE(automatic transfer switching equipment)
本文献已被 CNKI 维普 万方数据 等数据库收录!