Changes in polymer foils used in food packaging tested by using differential scanning calorimetry |
| |
Authors: | J Gajdo? Kljusuri? |
| |
Affiliation: | (1) Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva 6, 10000 Zagreb, Croatia |
| |
Abstract: | This work is an experimental study of the differential scanning calorimetry characterisation of polymer materials used in
food packaging materials, such as polypropylene (0.03 mm), polyethylene (0.1 and 0.03 mm), poly(D-(-)-Β-hydroxybutyrate) (powder),
two-layered polypropylene (0.064 mm), and two-layered polypropylene with poly-vinylidene-chloride (0.012/0.021). The polymer
stability was checked by simulation of conditions during food preparation in microwave ovens, sterilisation or rapid freezing.
The materials were tested in the temperature range from 40 to 200‡C at different scan rates from 2 to 30°C min−1 during heating or cooling. The enthalpies show a high correlation coefficient (0.964) with scan rate. All samples undergo
phase change in the temperature range from 107 to 173°C during heating and enthalpies are in the range from 31.8 to 71.1Jg−1. Upon subsequent cooling from 200°C, the temperature range of phase changes is shifted to lower temperatures from 86 to 102°C
with enthalpies ranging from 30.4 to 57.8 J g−1.
Experiments with exposure of polymers to microwave radiation and freezing prove that the phase change considering the temperature
range is very similar in all experiments. |
| |
Keywords: | Differential scanning calorimetry polymers food packaging enthalpy phase change |