首页 | 本学科首页   官方微博 | 高级检索  
     


Image quality and dose in spiral computed tomography
Authors:FR Verdun  RA Meuli  FO Bochud  C Imsand  S Raimondi  P Schnyder  JF Valley
Affiliation:Institut de Radiophysique Appliquée, Centre Universitaire, Lausanne, Switzerland.
Abstract:Image quality and dose produced by a spiral CT with various pitch values were investigated on the basis of test-object images and measurements of CT dose indexes. No major difference in image quality or dose was observed when comparing sequential and spiral mode acquisition with a pitch of one. Increase in pitch value produces a loss of contrast which leads to a loss of detectability. Nevertheless, in realistic protocols the image quality in the transverse plane remains acceptable up to pitch values of 1.3-1.6.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号