首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement uncertainty of adaptive Chirp-z transform
Authors:Petar Mostarac,Roman Malarić,Hrvoje Hegedu&scaron  
Affiliation:Department of Fundamentals of Electrical Engineering and Measurements, Faculty of Electrical Engineering and Computing, University of Zagreb, Croatia
Abstract:
In this paper analysis of measurement uncertainty of Adaptive Chirp-z transform (ACT) algorithm for power frequency measurement is presented. ACT is a new algorithm developed for real time monitoring of power frequency. Every element (hardware and software) of measurement chain is contributing to the total measurement uncertainty. The analysis of passive voltage dividers, analog-to-digital converters, numeric algorithms and processors (word length and type of arithmetic) are also presented. Estimated values of each contributing part of measurement chain are calculated to the final expression of measurement uncertainty.
Keywords:Chirp-z transform   Real time frequency measurement   Uncertainty analysis
本文献已被 ScienceDirect 等数据库收录!