多尺度复合毛细芯环路热管的传热特性
引用本文:王野,纪献兵,郑晓欢,徐进良.多尺度复合毛细芯环路热管的传热特性[J].化工学报,2015,66(6):2055-2061.
作者姓名:王野  纪献兵  郑晓欢  徐进良
作者单位:华北电力大学新能源电力系统国家重点实验室, 多相流与传热北京市重点实验室, 北京 102206
基金项目:国家自然科学基金项目(51276061);国家高技术研究发展计划项目(2013AA03A113);国家自然科学基金与广东省联合基金项目(U1034004);国家自然科学基金重点项目(51436004)。@@@@supported by the National Natural Science Foundation of China,the National High Technology Research and Development Program of China,the Joint Fund of the Natural Science Foundation of China and Guangdong Province,the Key Program of the National Natural Science Foundation of China
摘    要:为解决环路热管在蒸发腔不同区域对于毛细芯孔径尺度和热导率的不同需求, 制备了一种多尺度复合毛细芯环路热管, 并在不同加热功率、放置角度和冷却方式下对环路热管进行了热性能测试。实验发现该环路热管具有较好的传热性能, 在200 W加热功率下, 蒸发腔壁面中心温度Tc最低仅为64℃。与风冷方式相比, 冰冷方式可以显著强化环路热管的传热性能, 降低Tc和热阻。热阻最低为0.19 K·W-1。同时冰冷方式也有利于改善均温性。当加热功率不同时, 放置角度对环路热管温度及热阻的影响有所不同。另外, 多尺度复合毛细芯的应用有效地降低了热泄漏。随着加热功率的增加, 放置角度不同的LHP的热泄漏变化趋势不同。

关 键 词:环路热管  毛细芯  多尺度  传热特性  热泄漏  
收稿时间:2014-10-22
修稿时间:2015-03-07

Heat transfer characteristics of loop heat pipe with modulated composite porous wick
WANG Ye,JI Xianbing,ZHENG Xiaohuan,XU Jinliang.Heat transfer characteristics of loop heat pipe with modulated composite porous wick[J].Journal of Chemical Industry and Engineering(China),2015,66(6):2055-2061.
Authors:WANG Ye  JI Xianbing  ZHENG Xiaohuan  XU Jinliang
Affiliation:State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, Beijing Key Laboratory of Multiphase Flow and Heat Transfer, North China Electric Power University, Beijing 102206, China
Abstract:In order to suffice the different needs for pore size and thermal conductivity of wick in different evaporator regions of loop heat pipe (LHP), a LHP with modulated composite porous wick is constructed and investigated experimentally. The heat transfer characteristics of LHP are tested at different heating powers, inclination angles and cooling conditions. The results show that LHP has good heat transfer performances. The lowest temperature of the evaporator wall center (Tc) is only 64℃ at 200 W. The ice cooling can significantly promote LHP heat transfer performance, reducing Tc and thermal resistance, compared with the air cooling. The lowest thermal resistance is 0.19 K·W-1. Besides, the ice cooling is helpful to improving the temperature uniformity of the evaporator wall. The effects of inclination angles on temperature and thermal resistance vary with the increase of the heating power. At low heating power, Tc of LHP with evaporator and condenser being the same altitude is lower than that with evaporator below condenser. As the heating power rises, the former becomes higher than the latter. In addition, the heat leak from evaporator to compensation chamber can be reduced by applying the modulated composite porous wick. With the increase of heating power, the effects of inclination angles on heat leak are different.
Keywords:loop heat pipe  wick  multiscale  heat transfer  heat leak