首页 | 本学科首页   官方微博 | 高级检索  
     

700MW机组三级再热器管子泄漏原因分析
引用本文:范振宁.700MW机组三级再热器管子泄漏原因分析[J].广东电力,2009,22(6):60-63.
作者姓名:范振宁
作者单位:珠海发电厂,广东,珠海,519050
摘    要:介绍了珠海发电厂的三级再热器管子爆管的情况,通过对失效的高温再热器管进行宏观分析、光谱分析、金相分析,论证了爆管的原因是更换管夹或管夹螺栓时进行过焊接或气割作业误伤了管壁。对爆漏管子及有吹损情况的管子进行了更换,同时更换新管夹,未再发现其它异常情况。

关 键 词:再热器  爆管  T122

Causal Investigation into Tertiary Reheater Tube Leakage of 700 MW Unit
FAN Zhen-ning.Causal Investigation into Tertiary Reheater Tube Leakage of 700 MW Unit[J].Guangdong Electric Power,2009,22(6):60-63.
Authors:FAN Zhen-ning
Affiliation:FAN Zhen-ning (Zhuhai Power Station, Zhuhai, Guangdong 519(15(t, China)
Abstract:The tertiary reheater tube burst in Zhuhai Power Station is described. Through macroscopic, spectral and metallurgical analyses of the failed high-temperature reheater tubes, it is demonstrated that the tube burst was caused by the tube wall damage in the welding or gas cutting operation while replacing tube clamps or tube clamp bolts. No abnormalities have been found since the tubes with bursts and flue-dust-induced damages were replaced along with new tube clamps.
Keywords:T122
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号