一例空分设备主冷爆炸的原因分析 |
| |
引用本文: | 鲍建国. 一例空分设备主冷爆炸的原因分析[J]. 深冷技术, 2001, 0(6): 49-51 |
| |
作者姓名: | 鲍建国 |
| |
摘 要: | 合钢 15 0 0m3 /h空分设备主冷换热器发生爆炸 ,经分析认为是板翅式换热器“死区”有碳氢化合物集聚造成的 ,提出了预防措施
|
关 键 词: | 空分设备 主换热器 爆炸 原因分析 |
文章编号: | 1009-9425(2001)06-0049-03 |
修稿时间: | 2001-04-13 |
Analysis of an accident pertaining to main condenser explosion in an air separation plant |
| |
Abstract: | The explosion accident of main condenser in 1500m 3/h air separation plant operated in HefeiIron & Steel Group is described in the paper.It is found that the accident was caused by accumulation of hydrocarbons in the "dead area"of the plate fin heat exchangers.Furthermore preventive measures are presented. |
| |
Keywords: | Air separation plant Main heat exchanger Explosion.Cause analysis |
本文献已被 维普 万方数据 等数据库收录! |