首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of Low-Frequency Power on Etching Characteristics of 6H-SiC in C_4F_8/Ar Dual-Frequency Capacitively Coupled Plasma
Abstract:Dry etching of 6H silicon carbide(6H-SiC)wafers in a C_4Fs/Ar dual-frequency capacitively coupled plasma(DF-CCP)was investigated.Atomic force microscopy(AFM)and X-ray photoelectron spectroscopy(XPS)were used to measure the SiC surface structure and compositions,respectively.Optical emission spectroscopy(OES)was used to measure the relative concentration of F radicals in the plasma.It was found that the roughness of the etched SiC surface and the etching rate are directly related to the power of low-frequency(LF)source.At lower LF power,a smaller surface roughness and a lower etching rate are obtained due to weak bombardment of low energy ions on the SiC wafers.At higher LF power the etching rate can be efficiently increased,but the surface roughness increases too.Compared with other plasma dry etching methods,the DF-CCP can effectively inhibit C_xF_y films'deposition,and reduce surface residues.
Keywords:SiC  plasma etching  dual-frequency capacitively coupled plasma  X-ray photoelectron spectroscopy  optical emission spectroscopy
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏