首页 | 本学科首页   官方微博 | 高级检索  
     

410t/h锅炉减温水调节阀选型分析
引用本文:马欣. 410t/h锅炉减温水调节阀选型分析[J]. 西北电力技术, 2007, 0(5)
作者姓名:马欣
作者单位:中电国华神木发电有限公司 陕西
摘    要:针对国华神木发电公司减温水调节阀选型错误导致主汽温度控制困难的问题,分析了调节阀结构、调节阀静态特性曲线、调节阀选型参数的确定方法等,重新确定了合理的减温水调节阀选型参数,使主汽温度控制难的问题得到了解决。

关 键 词:减温水  调节阀  参数  选型

Type-choosing Analysis of Attempering Water Control Valve for 410 t/h Boiler
MA Xin. Type-choosing Analysis of Attempering Water Control Valve for 410 t/h Boiler[J]. Northwest China Electric Power, 2007, 0(5)
Authors:MA Xin
Abstract:In view of the main steam temperature control difficulty caused by type-choosing error of attempering water control valve for 410 t/h boiler in Guohua Shenmu Power Generating Co.,Ltd.,the methods to determine the control valve's structure,static characteristic curve and type-choosing parameters are analyzed, the rational parameters of type-choosing for attempering water control valve are also reconfirmed to solve the main steam temperature control difficulty.
Keywords:attempering water  control valve  parameters  type selection
本文献已被 CNKI 等数据库收录!