Theoretical and experimental study of a gas-coupled two-stage pulse tube cooler with stepped warm displacer as the phase shifter
Affiliation:1. Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry of Chinese Academy of Sciences, Beijing 100190, China;2. University of Chinese Academy of Sciences, Beijing 100049, China;3. Lihan Cryogenics Co., Ltd, Shenzhen 518055, China;4. Shanghai Institute of Technical Physics of Chinese Academy of Sciences, Shanghai 200083, China;1. Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yutian Road, Shanghai 200083, China;2. University of Chinese Academy of Sciences, No. 19A Yuquan Road, Beijing 100049, China;1. Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, CAS, Beijing 100190, China;2. University of Chinese Academy of Sciences, Beijing 100049, China;1. Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China;2. Laboratoire national de métrologie et d''essais-Conservatoire national des arts et métiers (LNE-Cnam), France;3. University of Chinese Academy of Sciences, Beijing 100049, China;4. Department of Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China;1. CAS Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Beijing 100190, China;2. University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:A compact and high efficiency cooler working at liquid hydrogen temperature has many important applications such as cooling superconductors and mid-infrared sensors. This paper presents a two-stage gas-coupled pulse tube cooler system with a completely co-axial configuration. A stepped warm displacer, working as the phase shifter for both stages, has been studied theoretically and experimentally in this paper. Comparisons with the traditional phase shifter (double inlet) are also made. Compared with the double inlet type, the stepped warm displacer has the advantages of recovering the expansion work from the pulse tube hot end (especially from the first stage) and easily realizing an appropriate phase relationship between the pressure wave and volume flow rate at the pulse tube hot end. Experiments are then carried out to investigate the performance. The pressure ratio at the compression space is maintained at 1.37, for the double inlet type, the system obtains 1.1 W cooling power at 20 K with 390 W acoustic power input and the relative Carnot efficiency is only 3.85%; while for the stepped warm displacer type, the system obtains 1.06 W cooling power at 20 K with only 224 W acoustic power input and the relative Carnot efficiency can reach 6.5%.
Keywords:Co-axial configuration  Stepped warm displacer  Pulse tube cooler  Double inlet
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号