首页 | 本学科首页   官方微博 | 高级检索  
     

氯化器爆炸事故分析
引用本文:岳丽燕.氯化器爆炸事故分析[J].氯碱工业,2012,48(9):34-35.
作者姓名:岳丽燕
作者单位:安徽八一化工股份有限公司,安徽蚌埠,233010
摘    要:分析了安徽八一化工股份有限公司氯化苯车间老系统氯化器尾气发生爆炸的两个原因——干苯含水较多和静电效应,提出了防范措施:在氯化器在开车之前,必须做干苯含水、氯气纯度分析,保证在分析合格后方可通氯开车;在日常工作中要按时检测静电接地电阻,并控制其阻值≤10 Ω,确保氯化器开车正常.

关 键 词:氯化器    氯气  爆炸

Analysis on an accident of chlorination reactor explosion
YUE Liyan.Analysis on an accident of chlorination reactor explosion[J].Chlor-Alkali Industry,2012,48(9):34-35.
Authors:YUE Liyan
Affiliation:YUE Liyan(Anhui Bayi Chemical Industry Co.,Ltd.,Bengbu 233010,China)
Abstract:Two causes of explosion of tail gas from chlorination reactor in the old system in the chlorobenzene workshop of Anhui Bayi Chemical Industry Co.,Ltd.were analyzed.The causes were high water content in dry benzene and electrostatic effect.The following preventive measures were put forward:(1) the water content in dry benzene and the purity of chlorine gas must be analyzed before start-up,and only after the analysis indexes were qualified can chlorine be fed to start up;(2) the earthing resistance of static electricity must be detected regularly in routine work and be controlled no greater than 10 Ω in order to ensure normal operation of chlorination reactor.
Keywords:chlorination reactor  benzene  chlorine gas  explosion