首页 | 本学科首页   官方微博 | 高级检索  
     

异型管曲率对气液膜分布及凝结换热特性的影响
引用本文:李慧君,李东,王业库,彭文平.异型管曲率对气液膜分布及凝结换热特性的影响[J].化工学报,2021,72(5):2560-2569.
作者姓名:李慧君  李东  王业库  彭文平
作者单位:华北电力大学能源动力与机械工程学院,河北保定071003
摘    要:基于双膜理论及边界层理论,建立了圆管、椭圆管、滴形管的管外气、液膜厚度及传热系数的数学模型。以圆管传热系数为依据进行了模型验证,计算结果与实验值的平均偏差约为6%,基本符合工程实际要求。在给定条件下,通过对不同曲率下各管型管外传热系数的计算,得到了气、液膜厚度的分布规律及换热特性。结果表明:在有效换热面积相同时,三种管型的气、液膜厚度,传热系数在一定角度下,随曲率的增大而增大;当曲率相同时,椭圆管传热系数最大,圆管最小。同时,分析了不同管型及其曲率对气、液膜排泄的影响机理和分离机理。为强化换热提供一定理论指导。

关 键 词:凝结  数学模拟  曲率  异型管  不凝结气体  
收稿时间:2020-09-22

Effect of the curvature of the special-shaped tube on gas-liquid film distribution and condensation heat transfer characteristics
LI Huijun,LI Dong,WANG Yeku,PENG Wenping.Effect of the curvature of the special-shaped tube on gas-liquid film distribution and condensation heat transfer characteristics[J].Journal of Chemical Industry and Engineering(China),2021,72(5):2560-2569.
Authors:LI Huijun  LI Dong  WANG Yeku  PENG Wenping
Affiliation:School of Energy Power and Mechanical Engineering, North China Electric Power University, Baoding 071003, Hebei, China
Abstract:Based on double film theory and boundary layer theory, mathematical models of gas and liquid film thickness and heat transfer coefficient of round tube, elliptical tube and drop tube are established. The model is verified based on the heat transfer coefficient of the round tube. The average deviation between the calculated result and the experimental value is about 6%, which basically meets the actual requirements of the project. Under the given conditions, distribution law of gas and liquid film thickness and heat transfer characteristics are obtained by calculating the heat transfer coefficient of each tube type under different curvature. The results show that: when the effective heat transfer area is the same, gas and liquid film thickness and heat transfer coefficient of the three types of tubes increase with the increase of curvature at a certain angle; when curvature is the same, the heat transfer coefficient of elliptical tube is the largest and that of circular tube is the smallest. At the same time, influence mechanism and separation mechanism of different tube shape and curvature on gas and liquid membrane discharge were analyzed. It provides some theoretical guidance for heat transfer enhancement.
Keywords:condensation  mathematical simulation  curvature  special-shaped tube  non-condensable gas  membrane  
本文献已被 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号