首页 | 本学科首页   官方微博 | 高级检索  
     

X射线荧光光谱法测定锌精矿中7组分
引用本文:石镇泰,牛艳红.X射线荧光光谱法测定锌精矿中7组分[J].甘肃冶金,2013(6):77-78,99.
作者姓名:石镇泰  牛艳红
作者单位:西北铅锌冶炼厂中心化验室,甘肃白银730900
摘    要:采用X射线荧光光谱法分析锌精矿中铅、锌、铁、硅、硫、铜、镉元素。以α系数法为主,用以校正共存元素间的吸收增强效应和谱线重叠影响,其中铅选用Lα做为分析线,其它元素全部选用Kɑ做为分析线;锌选用Rh做为内标元素,降低了基体干扰,大大提高了此方法对于分析不同矿脉的锌精矿的准确性与稳定性。此方法中各元素的检出限在11.16219.721μg·g-1之间。用本方法测定值与化学法、原子吸收法测定值进行比对,所测结果基本相符。对同一已知样品分析10次,求得所测定元素的RSD≤3%。

关 键 词:X射线荧光光谱法  锌精矿  七项元素  铑内标  硼酸

X-ray Fluorescence Spectrometry and Zinc Concentrate 7 Component
Affiliation:( Northwest of Lead and Zinc Smelter Central Laboratory, Baiyin 730900, China)
Abstract:X x-ray fluorescence spectrometry was adopted to determine contents of lead, zinc, iron, Silicon, sulfur, copper and cadmium in zinc concentrate, ct coefficient method was used for the correction of coexistence between elements absorp- tion enhancement effect and the line overlapping. L o~ as analysis line was choosen for lead, and K ct for other elements. Rh was selected as internal standard elements to reduce matrix interference and greatly improve accuracy and stability of the method for analysis of different vein of zinc concentrate. Detection limit for each element in this method was around 11.16 ~ 219. 721 ~g ~ g -1. Values by atomic absorption spectrometric determination method and chemical method were adopted to check against the values determined in this method and results showed that they conform well. Results of 10 times deter- mination on the same known sample showed that the determination of elements evaluated RSD 〈~3%.
Keywords:X-ray fluorescence spectrometry  zinc concentrate  seven elements  rhodium internal standard  boric acid
本文献已被 维普 等数据库收录!