Control Design Guidelines for Single-Phase Grid-Connected Photovoltaic Inverters With Damped Resonant Harmonic Compensators |
| |
Authors: | Castilla M. Miret J. Matas J. Garcia de Vicuna L. Guerrero J.M. |
| |
Affiliation: | Dept. of Electron. Eng., Tech. Univ. of Catalonia, Vilanova i la Geltru, Spain; |
| |
Abstract: | The injection of low-harmonic current to the electrical grid is nowadays regulated by international standards. In order to accomplish these standards, selective harmonic compensation is carried out in grid-connected photovoltaic inverters by means of resonant harmonic compensators. This paper gives a systematic design procedure for selecting the gains and parameters of these harmonic compensators. Other factors considered in the design process include frequency deviation, grid synchronization, and transient response. Both a design example meeting the requirements of grid interconnection and selected experimental results from a digital-signal-processor-based laboratory prototype are also reported. |
| |
Keywords: | |
|
|