首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal performance analysis on unit tube for heat pipe receiver
Authors:Haiting Cui   Zhenhui Wang   Yanshu Guo   Weiqiang Xu  Xiugan Yuan
Affiliation:aCollege of Electronic and Mechanical Engineering, Hebei University of Science and Technology, Shijiazhuang 050054, China;b505 Faculty, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
Abstract:
To reduce the mass and improve the thermal performance of the heat receiver, a heat pipe receiver was researched for the space solar dynamic power system. Corresponding mathematical and physical models were built, and a method was devised to provide a numerical equation by which the temperature of the containment canister outer wall, heat pipe wall temperature, working fluid exit temperature and the liquid PCM fraction of the total heat transfer tube were calculated and compared with those obtained from the baseline heat receiver. The results show that it is possible to improve receiver performance, to reduce the fluctuation of the working fluid temperature and to decrease the weight of the heat receiver.
Keywords:Solar dynamic power   Heat receiver   Heat pipe   Thermal performance
本文献已被 ScienceDirect 等数据库收录!