摘    要:为解决莱钢3#1080m3高炉铁口区门型冷却壁漏水情况,2011年3月采用焖炉方式进行年修,通过利用合理的冷却壁拆除、安装和密封方案及炉缸保水冷却、实时测温手段,成功更换了铁口区冷却壁和炉皮,消除了炉缸烧穿的隐患。

关 键 词:高炉  冷却壁  炉缸  灌浆

Replacing Practice of the Hearth Cooling Staves in Laiwu Steel's No.3 1080m~3 BF
WANG Fu-hua,JI Guang-gang,ZHUANG Xin-jun,CAO Hong-jie,XU Jun-xi.Replacing Practice of the Hearth Cooling Staves in Laiwu Steel's No.3 1080m~3 BF[J].Shandong Metallurgy,2011(5):69-70.
Authors:WANG Fu-hua  JI Guang-gang  ZHUANG Xin-jun  CAO Hong-jie  XU Jun-xi
Affiliation:WANG Fu-hua,JI Guang-gang,ZHUANG Xin-jun,CAO Hong-jie,XU Jun-xi(Laiwu Iron and Steel Co.,Ltd.,Laiwu 271104,China)
Abstract:In order to solve the water leakage situation of the door-type cooling staves in the taphole zone of Laiwu Steel's No.3 1 080 m3 BF,annual overhaul by banking manner was made in March 2011. Through the use of reasonable cooling walls demolished,installation and sealing solutions,and implementation of the hearth cooling,real-time temperature measurement means,the iron notch cooling walls and shell of blast furnace were successfully replaced. After replacement,the overall effect was good,eliminating the accid...