Some effects due to variations in turbulence integral length scales on the pressure distribution on wind-tunnel models of low-rise buildings |
| |
Authors: | A.E. Holdø E.L. Houghton F.S. Bhinder |
| |
Affiliation: | School of Engineering, The Hatfield Polytechnic, Hatfield AL10 9AB, Gt. Britain |
| |
Abstract: | The work described here consists of results from wind-tunnel tests on models of the Building Research Establishment's experimental building at Aylesbury. The use of several scale models of this building in uniform and in simulated atmospheric boundary-layer flows together with the results from the full-scale experiments allowed an assessment of the effect of variations in the ratio of the longitudinal-turbulence integral length scale to body dimension (Lx/D). This confirmed that the values of Lx/D have to be modelled correctly even in a non-homogeneous, non-isotropic turbulent flow in order to obtain model results that are representative of the full-scale situation. The present results also appear to confirm explanations given for similar results for homogeneous, isotropic turbulent flows. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |