Simultaneous determination of alkylbenzenesulfonates and dialkyltetralinsulfonates in water by liquid chromatography
Affiliation:1. Dipartimento di Chimica, Università “La Sapienza”, P.le Aldo Moro 5, 00185 Roma, Italy;2. Dipartimento di Scienze Ambientali, Università di Venezia, Calle Larga S. Marta 2137, I-30123, Venezia, Italy;1. Biometeorology and Soil Physics Group, University of British Columbia, Vancouver, Canada;2. Canadian Forest Service, Northern Forestry Center, Edmonton, Canada;1. National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka, 563-8577, Japan;2. Nara Institute of Science and Technology, 8916-5, Takayama-cho, Ikoma, Nara, 630-0192, Japan;1. Université de Bretagne Occidentale, CNRS, UMR LETG 6554, Institut Universitaire Européen de la Mer, Rue Dumont d''Urville, 29280, Plouzané, France;2. Environmental and Conservation Sciences, School of Veterinary and Life Sciences, Murdoch University, Perth, Western Australia, Australia;3. Université de Bretagne Occidentale, Inserm, EFS, UMR 1078, GGB, F-29200, Brest, France;4. Université de Bretagne Occidentale, Laboratoire LAboratoire d''Etudes et de Recherches en Sociologie, EA 3149, 3 Rue des Archives, 29238, Brest, France;5. Université de Bretagne Occidentale, Laboratoire Géoarchitecture, EA 7462, Faculté des Sciences et Techniques, 6 avenue Le Gorgeu, CS 93837, 29238, Brest Cedex 3, France
Abstract:A previous method based upon Liquid Chromatography (HPLC) with fluorometric detection for determining linear alkylbenzenesulfonates (LAS) in aqueous environmental samples has been modified for extending it to the monitoring of dialkyltetralinsulfonates (DATS). DATS are reaction byproducts of LAS surfactant synthesis. 10, 100, 200, 1000 ml of respectively untreated sewage, treated one, riverwater and groundwater samples have been extracted by a 0.5-g Graphitized Carbon Black (GCB) cartridge. After sample extraction, co-extracted basic, neutral and weakly acidic compounds have been washed out by a formic acid containing solvent system. DATS and LAS have been then reextracted by passing through the cartridge a basified organic eluant mixture. After solvent removal and residue reconstitution by a suitable solvent system, the subfractionation of the analytes have been achieved by chromatographing them on a C-8 reverse-phase HPLC column. Recovery studies have shown that DATS have been quantitatively extracted by the GCB cartridge. By this procedure, the concentrations in water of DATS entering and leaving two sewage treatment plants in Rome have been monthly monitored over 1 year. With respect to LAS, the higher resistance to biodegradation of DATS has been demonstrated by comparative biodegradation tests. Analysis of a sewage-contaminated groundwater sample has shown that, although DATS are minor components in LAS formulations, the concentration of the former was even higher than that of the latter, with C10 DATS being the most abundant species.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号