首页 | 本学科首页   官方微博 | 高级检索  
     

电感耦合等离子体质谱法同时测定马鹿皮中9种元素
引用本文:姜鑫,董宇,刘静,王震红,白松.电感耦合等离子体质谱法同时测定马鹿皮中9种元素[J].食品安全质量检测技术,2018,9(12):3183-3187.
作者姓名:姜鑫  董宇  刘静  王震红  白松
作者单位:辽宁省药品检验检测院;沈阳药科大学
摘    要:目的建立微波消解-电感耦合等离子体质谱(inductively coupled plasma mass spectrometry,ICP-MS)法同时测定马鹿皮中钠、锰、镁、钾、钙、铁、硒、铜和锌9种元素的含量的方法。方法样品经硝酸-过氧化氢微波消解后,通过在线加入内标溶液校正,以72Ge为内标,采用ICP-MS测定马鹿皮中钠、锰、镁、钾、钙、铁、硒、铜和锌9种元素的含量。结果 9种元素线性良好,相关系数为0.9995~1.0000;钠、锰、镁、钾、钙、铁、硒、铜和锌的检出限分别为4、0.007、0.2、1、1、0.3、0.004、0.009、0.05 mg/kg;9种元素的回收率在86%~116%之间;相对标准偏差(relative standard deviation,RSD)≤7.2%(n=6)。结论该方法灵敏度高、稳定性好,可以满足马鹿皮中钠、锰、镁、钾、钙、铁、硒、铜和锌的测定。

关 键 词:电感耦合等离子体质谱法    马鹿皮    微波消解
收稿时间:2018/5/2 0:00:00
修稿时间:2018/6/21 0:00:00

Simultaneous determination of 9 kinds of elements in red deer skin by inductively coupled plasma mass spectrometry
Jiang Xin,DONG Yu,LIU Jing,WANG Zhen-Hong and BAI Song.Simultaneous determination of 9 kinds of elements in red deer skin by inductively coupled plasma mass spectrometry[J].Food Safety and Quality Detection Technology,2018,9(12):3183-3187.
Authors:Jiang Xin  DONG Yu  LIU Jing  WANG Zhen-Hong and BAI Song
Affiliation:Liaoning Institute for Drug Control,Liaoning Institute for Drug Control,Liaoning Institute for Drug Control,Liaoning Institute for Drug Control and Shenyang Pharmaceutical University
Abstract:Objective To establish a method for simultaneous determination of 9 elements such as sodium, manganese, magnesium, potassium, calcium, iron, selenium, copper and zinc in red deer skin by microwave digestion-inductively coupled plasma mass spectrometry (ICP-MS). Methods The sample was digested with nitric acid-hydrogen peroxide by microwaves and corrected by on-line addition of 72G as an internal standard solution, and the content of sodium, manganese, magnesium, potassium, calcium, iron, selenium, copper and zinc in the deer skin were determinate by ICP-MS. Results Nine elements had good linear relationship, and the correlation coefficient were 0.9995~1.0000. The limits of detection of sodium, manganese, magnesium, potassium, calcium, iron, selenium, copper and zinc were 4, 0.007, 0.2, 1, 1, 0.3, 0.004, 0.009, 0.05 mg/kg, respectively. The recoveries of 9 elements were in the range of 86%~116%. The relative standard deviations (RSD, n=6) of the method were less than 7.2%. Conclusion The method has high sensitivity and good stability, which is suitable for the determination of sodium, manganese, magnesium, potassium, calcium, iron, selenium, copper and zinc in red deer skin.
Keywords:inductively coupled plasma mass spectrometry  red deer skin  microwave digest
本文献已被 CNKI 等数据库收录!
点击此处可从《食品安全质量检测技术》浏览原始摘要信息
点击此处可从《食品安全质量检测技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号